We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical > Power Distribution & Generation (ET04) - (9505 Products)


Lighting & Electrical > Power Distribution & Generation (ET04)


Schneider Electric - 30 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 36mm Wide


Item #: 69528560
Brand: Schneider Electric
Model #: 60149
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 30
Number of Poles 1
Breaking Capacity 10 kA @ 125 VDC; 10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type DIN Rail Mount; Fixed Mount
Voltage 125 VDC; 240 VAC; 60 VDC
Durability 20000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (mm) 73
Overall Height (mm) 107
Overall Width (mm) 36
Standards Met CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type Handle

$270.41

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 63 Amp, 480Y/277 Volt, 4 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2, 18-3 AWG


Item #: 46109872
Brand: Schneider Electric
Model #: M9F22463
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 63
Number of Poles 4
Breaking Capacity 10 kA @ 240 VAC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 5 kA @ 480Y/277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-2; 18-3
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 2.8400
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$458.17

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 100 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 54522289
Brand: Square D
Model #: HJL36100
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 100
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 20 kA @ 250 VDC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$3,192.63

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 400 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 AWG, 8.05 Inch Deep x 12.86 Inch High x 8.27 Inch Wide


Item #: 56765571
Brand: Square D
Model #: U31XAAUOYH1Y029
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 400
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Busbar
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 8.0500
Overall Height (Decimal Inch) 12.8600
Overall Width (Decimal Inch) 8.2700
Standards Met IEC 60947-2; OSHA Requirements; UL 489
Reset Actuator Type Toggle Switch

$12,363.09

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 V, 18 kA at 347 VAC, 35 kA at 277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41394479
Brand: Square D
Model #: BGA160501
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 50
Number of Poles 1
Breaking Capacity 65 kA @ 240 V; 18 kA @ 347 VAC; 35 kA @ 277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$605.96

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 25 Amp, 125 VDC, 240 VAC, 60 VDC, 3 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 54mm Wide


Item #: 69528446
Brand: Schneider Electric
Model #: 60197
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 25
Number of Poles 3
Breaking Capacity 10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type DIN Rail Mount; Fixed Mount
Voltage 125 VDC; 240 VAC; 60 VDC
Durability 20000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (mm) 73
Overall Height (mm) 107
Overall Width (mm) 54
Standards Met CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type Handle

$367.78

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 30 Amp, 240 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 20 kA at 240 VAC Breaking Capacity, 14-2 AWG, 76mm Deep x 81mm High x 54mm Wide


Item #: 56785710
Brand: Schneider Electric
Model #: 60282
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 30
Number of Poles 3
Breaking Capacity 20 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 240 VAC
Wire Size (sq mm) 1-35
Wire Size (AWG) 14-2
Durability 4000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 54
Overall Width (Decimal Inch) 2.1300
Standards Met CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; HID (High Intensity Discharge) Rated; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117
Reset Actuator Type Handle

$550.90

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Value Collection - Circuit Breakers Circuit Breaker Type: Type III Circuit Breaker Amperage: 20


Item #: 66445438
Brand: Value Collection
Exact Tooling IR#: 04

Product Specifications

Circuit Breakers; Circuit Breaker Type: Type III Circuit Breaker ; Amperage: 20 ; Tripping Mechanism: Manual ; Mounting Type: Plug-in ; Voltage: 12 VDC
Circuit Breaker Type Type III Circuit Breaker
Amperage 20
Tripping Mechanism Manual
Mounting Type Plug-in
Voltage 12 VDC

$19.33

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 8 Amp, 600 VAC, 3 Pole, DIN Rail Mounted, Panel Mount Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78-1/2mm Deep x 89mm High x 45mm Wide


Item #: 56828700
Brand: Schneider Electric
Model #: GV2RT03
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 8
Number of Poles 3
Breaking Capacity 100 kA @ 220/230 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type DIN Rail Mounted; Panel Mount
Voltage 600 VAC
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78-1/2
Overall Height (mm) 89
Overall Length (mm) 44-1/2
Overall Width (mm) 45
For Use With Motor Operators
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL
Reset Actuator Type Rocker Switch

$278.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 60 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56745714
Brand: Square D
Model #: HJP36060CAB
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 60
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$4,772.44

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 40 Amp, 240 VAC, 2 Pole, Bolt On Miniature Circuit Breaker - 8-2 AWG


Item #: 69529451
Brand: Square D
Model #: QOB240
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 40
Number of Poles 2
Terminal Connection Type Box Lugs
Mounting Type Bolt-on
Voltage 240 VAC
Wire Size (AWG) 8-2
Standards Met CSA; RoHS Compliant; UL Listed

$118.27

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 50 Amp, 250 VDC, 1 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2, 18-4, 18-6 AWG


Item #: 46111415
Brand: Schneider Electric
Model #: M9U31150
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60H-DC - Supplementary Protection for Direct Current
Amperage 50
Number of Poles 1
Breaking Capacity 10 kA @ 220 VDC; 6 kA @ 250 VDC; 20 kA @ 110 VDC; 5 kA @ 12-250 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 250 VDC
Wire Size (AWG) 18-2; 18-4; 18-6
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 0.7100
For Use With OEM Panel
Standards Met UL 1077; IEC; CCC
Reset Actuator Type Toggle Switch

$215.85

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 125 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56748429
Brand: Square D
Model #: HJL36125C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 125
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 20 kA @ 250 VDC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$10,102.98

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 800 Amp, 600 V, 3 Pole, Panel Mount Molded Case Circuit Breaker - Multiple Breaking Capacity Ratings


Item #: 49753593
Brand: Square D
Model #: MGM36800
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 800
Number of Poles 3
Breaking Capacity 18 kA @ 600 V; 35 kA @ 480 V; 65 kA @ 240 V
Mounting Type Panel Mount
Voltage 600 V
Standards Met CSA; UL Listed

$14,380.25

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 6 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46110276
Brand: Schneider Electric
Model #: M9F22206
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 6
Number of Poles 2
Breaking Capacity 14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 10 kA @ 125 VDC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 1.4200
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$221.97

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Cooper Bussmann - Circuit Breakers Circuit Breaker Type: Type III Circuit Breaker Amperage: 120


Item #: 61497400
Brand: Cooper Bussmann
Model #: BK/CB185-120
Exact Tooling IR#: 04

Product Specifications

Circuit Breakers; Circuit Breaker Type: Type III Circuit Breaker ; Amperage: 120 ; Tripping Mechanism: Manual ; Terminal Connection Type: Blade ; Mounting Type: Flush Mount ; Overall Depth (Decimal Inch): 1/2
Circuit Breaker Type Type III Circuit Breaker
Amperage 120
Tripping Mechanism Manual
Terminal Connection Type Blade
Mounting Type Flush Mount
Overall Depth (Decimal Inch) 1/2
Overall Depth (mm) 12.70
Overall Height (mm) 23.30
Overall Height (Decimal Inch) 0.9200
Overall Width (mm) 31.80
Overall Width (Decimal Inch) 1-1/4
Standards Met SAE J1117
Reset Actuator Type Button

$86.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 45 Amp, 240 VAC, 2 Pole, Bolt On Miniature Circuit Breaker - 8-2 AWG


Item #: 69660561
Brand: Square D
Model #: QOB245
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 45
Number of Poles 2
Terminal Connection Type Box Lugs
Mounting Type Bolt-on
Voltage 240 VAC
Wire Size (AWG) 8-2
Standards Met CSA; RoHS Compliant; UL Listed

$116.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 6 Amp, 480Y/277 Volt, 3 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46120416
Brand: Schneider Electric
Model #: M9F23306
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 6
Number of Poles 3
Breaking Capacity 14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 2.1300
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$320.72

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 60 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56739428
Brand: Square D
Model #: HDL36060AA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 60
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$2,146.29

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 V, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings


Item #: 56757156
Brand: Square D
Model #: LAL36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 10 kA @ 125 VDC; 10 kA @ 250 VDC; 22 kA @ 600 VAC; 30 kA @ 480 VAC; 42 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 V
Standards Met CCC; CSA; IEC; UL Listed

$4,772.59

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It