Square D - 200 Amp, 250 VDC, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG
Item #: 56744527
Brand: Square D
Model #: JDL26200C
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
200
Number of Poles
2
Breaking Capacity
14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
3/0
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 50 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide
Item #: 56739501
Brand: Square D
Model #: HDL36050AA
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
50
Number of Poles
3
Breaking Capacity
14 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Overall Depth (Decimal Inch)
4.3600
Overall Depth (mm)
110.80
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 15 Amp, 240 VAC, 1 Pole, Panel Mount Miniature Circuit Breaker - 14-2 AWG
Item #: 56836851
Brand: Square D
Model #: QOU1151200
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
15
Number of Poles
1
Terminal Connection Type
Box Lugs
Mounting Type
Panel Mount
Voltage
240 VAC
Wire Size (AWG)
14-2
For Use With
Auxiliary Switch 1A
Standards Met
CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 15 Amp, 125 VDC, 277/480 VAC, 1 Pole, Bolt On Molded Case Circuit Breaker - Thermal Magnetic Trip, 14-10 AWG, 66.7mm Deep x 4 Inch High x 1 Inch Wide
Item #: 04882619
Brand: Eaton Cutler-Hammer
Model #: GHB1015
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
15
Number of Poles
1
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Bolt-on
Voltage
125 VDC; 277/480 VAC
Wire Size (AWG)
14-10
Overall Depth (Decimal Inch)
2.6300
Overall Depth (mm)
66.70
Overall Height (mm)
101.60
Overall Height (Inch)
4
Overall Width (Inch)
1
Standards Met
CSA Listed; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 20 Amp, 240 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 20 kA at 240 VAC Breaking Capacity, 14-4 AWG, 73mm Deep x 123.4mm High x 54mm Wide
Item #: 56839012
Brand: Schneider Electric
Model #: 60280
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
20
Number of Poles
3
Breaking Capacity
20 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
240 VAC
Wire Size (sq mm)
2-25
Wire Size (AWG)
14-4
Durability
10000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
2.8740
Overall Depth (mm)
73
Overall Height (mm)
123.40
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
54
Overall Width (Decimal Inch)
2.1300
Standards Met
CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; HID (High Intensity Discharge) Rated; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117
Reset Actuator Type
Handle
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 40 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide
Item #: 56745755
Brand: Square D
Model #: HJN36040
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
40
Number of Poles
3
Breaking Capacity
25 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Plug-in
Mounting Type
Unit Mount
Voltage
600 VAC
Wire Size (AWG)
14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Overall Depth (Decimal Inch)
4.3600
Overall Depth (mm)
110.80
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 13 Amp, 277 Volt, 1 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46109781
Brand: Schneider Electric
Model #: M9F23113
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60SP - Supplementary Protection
Amperage
13
Number of Poles
1
Breaking Capacity
10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 65 VDC; 3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
0.7100
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 25 Amp, 600Y/347 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41399437
Brand: Square D
Model #: BDA36025
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
25
Number of Poles
3
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 480 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 800 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 18 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum), 3/0 (Copper) AWG, 8.05 Inch Deep x 16.16 Inch High x 8.27 Inch Wide
Item #: 56762339
Brand: Square D
Model #: PGP36080U43A
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
800
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600 VAC
Wire Size (AWG)
3/0 (Aluminum); 3/0 (Copper)
Overall Depth (Decimal Inch)
8.0500
Overall Height (Decimal Inch)
16.1600
Overall Width (Decimal Inch)
8.2700
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 40 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14-3/0 AWG, 87.4mm Deep x 162.6mm High x 104.7mm Wide
Item #: 56746050
Brand: Square D
Model #: HJL36040T
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
40
Number of Poles
3
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
104
Overall Depth (Decimal Inch)
3.4400
Overall Depth (mm)
87.40
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
For Use With
Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met
CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 2 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 240 VAC Breaking Capacity, 14-4 AWG, 73mm Deep x 123.4mm High x 18mm Wide
Item #: 69669364
Brand: Schneider Electric
Model #: 60203
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
2
Number of Poles
1
Breaking Capacity
10 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
120/240 VAC
Wire Size (sq mm)
2-25
Wire Size (AWG)
14-4
Durability
10000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
2.8740
Overall Depth (mm)
73
Overall Height (mm)
123.40
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
18
Overall Width (Decimal Inch)
0.7100
Standards Met
CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117; UL Listed for SWD Applications
Reset Actuator Type
Handle
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 225 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG
Item #: 54522164
Brand: Square D
Model #: JLL36225
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
225
Number of Poles
3
Breaking Capacity
100 kA @ 480 VAC; 125 kA @ 240 VAC; 20 kA @ 250 VDC; 50 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
3/0
Standards Met
RoHS Compliant
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 90 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41383514
Brand: Square D
Model #: BGA24090Y1
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
90
Number of Poles
2
Breaking Capacity
65 kA @ 240 VAC; 35 kA @ 480Y/277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
480Y/277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 5 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 36mm Wide
Item #: 69528529
Brand: Schneider Electric
Model #: 60157
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
5
Number of Poles
1
Breaking Capacity
10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Tunnel
Mounting Type
DIN Rail Mount; Fixed Mount
Voltage
125 VDC; 240 VAC; 60 VDC
Durability
20000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (mm)
73
Overall Height (mm)
107
Overall Width (mm)
36
Standards Met
CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type
Handle
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 150 Amp, 250 VDC, 600 VAC, 2 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 69.7mm Wide
Item #: 56739691
Brand: Square D
Model #: HDL26150SA
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
150
Number of Poles
2
Breaking Capacity
14 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Overall Depth (Decimal Inch)
4.3600
Overall Depth (mm)
110.80
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
69.70
Overall Width (Decimal Inch)
2.7400
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 50 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG
Item #: 56746027
Brand: Square D
Model #: HJL36050C
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
50
Number of Poles
3
Breaking Capacity
100 kA @ 240 VAC; 20 kA @ 250 VDC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0
Standards Met
RoHS Compliant
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 150 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide
Item #: 56746381
Brand: Square D
Model #: HGL36150LV
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
150
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Overall Depth (Decimal Inch)
4.3600
Overall Depth (mm)
110.80
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 80 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41383936
Brand: Square D
Model #: BGL26080
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
80
Number of Poles
2
Breaking Capacity
65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 600 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 2 AWG
Item #: 54522578
Brand: Square D
Model #: LGL36600U31X
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
600
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 VAC
Wire Size (AWG)
2
Standards Met
CCC; CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 1 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46118006
Brand: Schneider Electric
Model #: M9F21201
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60SP - Supplementary Protection
Amperage
1
Number of Poles
2
Breaking Capacity
14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 10 kA @ 125 VDC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
480Y/277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
1.4200
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It