Lighting & Electrical > Power Distribution & Generation (ET04) - (9505 Products)


Lighting & Electrical > Power Distribution & Generation (ET04)


Square D - 150 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56741523
Brand: Square D
Model #: HJP36150U44X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$10,595.08

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 100 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56740335
Brand: Square D
Model #: HGL36100U33X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 100
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$2,791.77

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 5 Amp, 125 VDC, 240 VAC, 60 VDC, 1 Pole, DIN Rail Mount, Fixed Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 107mm High x 36mm Wide


Item #: 69669307
Brand: Schneider Electric
Model #: 60140
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 5
Number of Poles 1
Breaking Capacity 10 kA @ 125 VDC; 10 kA @ 240 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type DIN Rail Mount; Fixed Mount
Voltage 125 VDC; 240 VAC; 60 VDC
Durability 20000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (mm) 73
Overall Height (mm) 107
Overall Width (mm) 36
Standards Met CSA C22.2 No. 5.2; IEC 60947-2; RoHS Compliant; UL 489
Reset Actuator Type Handle

$282.82

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 480Y/277 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41383647
Brand: Square D
Model #: BGA34050Y
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 50
Number of Poles 3
Breaking Capacity 65 kA @ 240 VAC; 35 kA @ 480Y/277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 480Y/277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$1,239.15

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 40 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 136mm Deep x 132mm High x 55mm Wide


Item #: 69649135
Brand: Schneider Electric
Model #: GV3P13
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 40
Number of Poles 3
Breaking Capacity 100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 12 kA @ 500 VAC; 50 kA @ 440 VAC; 6 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 50000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 136
Overall Height (mm) 132
Overall Width (mm) 55
For Use With TeSys GV3
Standards Met ATEX; Bureau Veritas; CCC; CSA; DNV; GL; GOST; IEC 60947-2; LROS; RINA; UL

$424.72

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 100 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 69647337
Brand: Square D
Model #: HDL36100C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 100
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0

$1,877.60

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 1 Pole, Plug In Type BR Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-4 AWG


Item #: 00105205
Brand: Eaton Cutler-Hammer
Model #: BR150
Exact Tooling IR#: 04

Features and Benefits

Type BR circuuit breakers are used in load centers, panelboards, or similar devices. They are available in 1,2 or with 3 poles.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Type BR Circuit Breaker
Amperage 50
Number of Poles 1
Breaking Capacity 10 kA
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Plug-in
Voltage 120/240 VAC
Wire Size (AWG) 14-4
Standards Met NEC 2008; NEC 2011; NEC 2014; UL Listed 67

$43.58

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 277 V, 1 Pole, Bolt On Miniature Circuit Breaker - 18 kA Breaking Capacity, 12, 14 AWG


Item #: 54421987
Brand: Square D
Model #: EDB14050
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 50
Number of Poles 1
Breaking Capacity 18 kA
Terminal Connection Type Lug
Mounting Type Bolt-on
Voltage 277 V
Wire Size (AWG) 12; 14
For Use With NF Panelboard
Standards Met CSA; HACR Rated; UL Listed

$202.96

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 60 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41383548
Brand: Square D
Model #: BGA24060Y1
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 60
Number of Poles 2
Breaking Capacity 65 kA @ 240 VAC; 35 kA @ 480Y/277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 480Y/277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$991.32

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 80 Amp, 250 VDC, 600 VAC, 3 Pole, Individually Mounted Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 12-1/0 (Aluminum), 14-1/0 (Copper) AWG, 4.13 Inch Deep x 6 Inch High x 4-1/2 Inch Wide


Item #: 56759210
Brand: Square D
Model #: FHL360801380
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 80
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Individually-Mounted
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 12-1/0 (Aluminum); 14-1/0 (Copper)
Overall Depth (Decimal Inch) 4.1300
Overall Height (Decimal Inch) 6
Overall Width (Decimal Inch) 4-1/2
Standards Met CSA Certified; Federal Specification W-C 375 b/Gen; IEC Rated; UL Listed
Reset Actuator Type Toggle Switch

$4,039.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Amp, 600Y/347 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399353
Brand: Square D
Model #: BDA36110
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 110
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$1,749.66

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 20 Amp, 240 VAC, 3 Pole, Bolt On Miniature Circuit Breaker - 14-8 AWG


Item #: 69529428
Brand: Square D
Model #: QOB320
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 20
Number of Poles 3
Terminal Connection Type Pressure Plate
Mounting Type Bolt-on
Voltage 240 VAC
Wire Size (AWG) 14-8
Standards Met CSA; RoHS Compliant; UL Listed

$331.27

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 80 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41396680
Brand: Square D
Model #: BGL36080LU
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 80
Number of Poles 3
Breaking Capacity 65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Reset Actuator Type Toggle Switch

$1,688.54

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 100 Amp, 240 VAC, 3 Pole, Bolt On Miniature Circuit Breaker - 4-2/0 AWG


Item #: 69660413
Brand: Square D
Model #: QOB3100VH
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 100
Number of Poles 3
Terminal Connection Type Box Lugs
Mounting Type Bolt-on
Voltage 240 VAC
Wire Size (AWG) 4-2/0
Standards Met CSA; RoHS Compliant; UL Listed

$759.72

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, 250 VDC, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56739824
Brand: Square D
Model #: HDL26030C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 30
Number of Poles 2
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$1,617.85

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 25 Amp, 120/240 VAC, 2 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide


Item #: 56788433
Brand: Square D
Model #: QOUQ225
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 25
Number of Poles 2
Breaking Capacity 10 kA @ 120/240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type DIN Rail Mounted; Flush Mount; Surface Mount
Voltage 120/240 VAC
Wire Size (AWG) 14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch) 2.9200
Overall Depth (mm) 74
Overall Height (mm) 103
Overall Height (Decimal Inch) 4.0500
Overall Width (mm) 19
Overall Width (Decimal Inch) 3/4
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type Toggle Switch

$146.47

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 400 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 2 AWG


Item #: 56765514
Brand: Square D
Model #: LGL36400CU44X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 400
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 2
Standards Met CCC; CSA; IEC; UL Listed

$15,361.91

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56748346
Brand: Square D
Model #: HJL36050CA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 50
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$3,805.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 400 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 AWG, 5 Inch Deep x 7.52 Inch High x 4.12 Inch Wide


Item #: 56765126
Brand: Square D
Model #: LJM36400CU43X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 400
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Height (Decimal Inch) 7.5200
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$18,582.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 15 Amp, 480Y/277 Volt, 3 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46119251
Brand: Schneider Electric
Model #: M9F42315
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60BP - Branch Protection
Amperage 15
Number of Poles 3
Breaking Capacity 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 4.0600
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 2.1300
For Use With OEM Panel
Standards Met UL 489; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$369.44

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It