Square D - 70 Amp, 250 VDC, 480 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 480/600 VAC Breaking Capacity, 12-1/0 (Aluminum), 14-1/0 (Copper) AWG, 4.13 Inch Deep x 6 Inch High x 3 Inch Long


Item #: 69525848
Brand: Square D
Model #: FAL24070
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 70
Number of Poles 2
Breaking Capacity 18 kA @ 480/600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 480 VAC
Wire Size (AWG) 12-1/0 (Aluminum); 14-1/0 (Copper)
Minimum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 4.1300
Overall Height (Inch) 6
Overall Length (Inch) 3
For Use With Industrial Enclosures & Switchboards
Standards Met CSA Certified; Federal Specification W-C 375 b/Gen; IEC Rated; UL Listed
Reset Actuator Type Toggle Switch

$843.37

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 16 Amp, 480Y/277 Volt, 4 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46109948
Brand: Schneider Electric
Model #: M9F22416
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 16
Number of Poles 4
Breaking Capacity 14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 2.8400
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$423.55

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 400 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 25 kA at 600 VAC Breaking Capacity, 2 AWG, 5 Inch Deep x 7.52 Inch High x 4.12 Inch Wide


Item #: 56765209
Brand: Square D
Model #: LJL36400U31XSK
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 400
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 2
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 5
Overall Height (Decimal Inch) 7.5200
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$14,961.66

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 35 Amp, 277 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 V, 35 kA at 277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41394289
Brand: Square D
Model #: BGA140351
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 35
Number of Poles 1
Breaking Capacity 65 kA @ 240 V; 35 kA @ 277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$492.09

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 45 Amp, 480Y/277 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41383654
Brand: Square D
Model #: BGA34045Y
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 45
Number of Poles 3
Breaking Capacity 65 kA @ 240 VAC; 35 kA @ 480Y/277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 480Y/277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$1,239.15

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 70 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56745987
Brand: Square D
Model #: HJL36070AB
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 70
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$4,381.90

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 250 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 2 AWG


Item #: 56765555
Brand: Square D
Model #: LGL36250CU31X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 250
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 2
Standards Met CCC; CSA; IEC; UL Listed

$9,673.40

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 40 Amp, 440 VAC, 3 Pole, Clip, DIN Rail Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 81mm High x 54mm Wide


Item #: 56787658
Brand: Schneider Electric
Model #: 25508
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 40
Number of Poles 3
Breaking Capacity 20 kA @ 440 VAC; 25 kA @ 400-415 VAC; 30 kA @ 125 VDC; 50 kA @ 125 VDC; 50 kA @ 230-240 VAC; 60 kA @ 250 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type Clip; DIN Rail Mount
Voltage 440 VAC
Durability 20000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -13
Overall Depth (mm) 73
Overall Height (mm) 81
Overall Width (mm) 54
For Use With C60 Accessories; C60 Auxiliary
Standards Met EN 60898; EN/IEC 60947-2
Reset Actuator Type Toggle Switch

$714.08

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 100 Amp, 240 VAC, 1 Pole, Panel Mount Miniature Circuit Breaker - 14-2 AWG


Item #: 56789191
Brand: Square D
Model #: QOU11001200
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 100
Number of Poles 1
Terminal Connection Type Box Lugs
Mounting Type Panel Mount
Voltage 240 VAC
Wire Size (AWG) 14-2
For Use With Auxiliary Switch 1A
Standards Met CSA; IEC; RoHS Compliant; UL Listed

$429.57

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 225 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56744295
Brand: Square D
Model #: JDL36225C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 225
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0

$5,076.73

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 800 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56762131
Brand: Square D
Model #: PJL36080CU31A
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 800
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Standards Met CSA; IEC; UL Listed

$37,209.65

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 20 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56746670
Brand: Square D
Model #: HGL36020C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 20
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 20 kA @ 250 VDC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$2,775.47

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Amp, 480Y/277 Volt, 1 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46119871
Brand: Schneider Electric
Model #: M9F43103
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60BP - Branch Protection
Amperage 3
Number of Poles 1
Breaking Capacity 3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC; 10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 60 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 4.0600
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 0.7100
For Use With OEM Panel
Standards Met UL 489; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$127.27

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 800 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56767866
Brand: Square D
Model #: PJL36080M68
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 800
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Standards Met CSA; IEC; UL Listed

$16,152.70

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 70 Amp, 120/240 VAC, 24 VDC, 48 VDC, 80 VDC, 2 Pole, Plug In Miniature Circuit Breaker - Thermal Magnetic Trip, 8-1/0 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 2 Inch Wide


Item #: 04882346
Brand: Eaton Cutler-Hammer
Model #: HQP2070
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 70
Number of Poles 2
Tripping Mechanism Thermal-Magnetic
Mounting Type Plug-in
Voltage 120/240 VAC; 24 VDC; 48 VDC; 80 VDC
Wire Size (AWG) 8-1/0
Overall Depth (Inch) 2-3/8
Overall Height (Inch) 2-15/16
Overall Width (Inch) 2
Standards Met CSA Listed; Federal Specification W-C-375b; UL Listed 489

$439.18

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 50 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41383985
Brand: Square D
Model #: BGL26050LU
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 50
Number of Poles 2
Breaking Capacity 65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$1,288.51

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 600 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, 110mm Deep x 340mm High x 140mm Wide


Item #: 56765563
Brand: Square D
Model #: LGF36600U31X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 600
Number of Poles 3
Tripping Mechanism Electronic
Terminal Connection Type Busbar
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 4.3300
Overall Depth (mm) 110
Overall Height (mm) 340
Overall Height (Decimal Inch) 13.3800
Overall Width (mm) 140
Overall Width (Decimal Inch) 5.5100
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$12,177.57

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 20 Amp, 240 VAC, 1 Pole, Panel Mount Miniature Circuit Breaker - 14-2 AWG


Item #: 56789092
Brand: Square D
Model #: QOU1201042
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 20
Number of Poles 1
Terminal Connection Type Box Lugs
Mounting Type Panel Mount
Voltage 240 VAC
Wire Size (AWG) 14-2
For Use With Shunt Trip 12/24 VAC/VDC
Standards Met CSA; IEC; RoHS Compliant; UL Listed

$319.38

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 25 Amp, 240 VAC, 2 Pole, Residual Current Device


Item #: 69661148
Brand: Schneider Electric
Model #: 60951
Exact Tooling IR#: 04

Features and Benefits

Residual Current Devices (RCDs) are used for detecting imbalance in currents and protecting against fatal shocks. They trip only when there is an earth fault current. They cannot detect overloads.

Product Specifications

25 Amp, 240 VAC, 2 Pole, Residual Current Device -
Circuit Breaker Type Residual Current Device
Amperage 25
Number of Poles 2
Terminal Connection Type Tunnel
Voltage 240 VAC
Durability 20000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -13
Standards Met IEC 61008; RoHS Compliant; UL 1053
Reset Actuator Type Toggle Switch

$643.16

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 125 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56747405
Brand: Square D
Model #: HDL36125AASA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 125
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$5,600.49

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It