Lighting & Electrical Products - Power Distribution & Generation Equipment For Sale | All Tool & Supply - (9098 Products)
Schneider Electric - 6 Amp, 500 VDC, 2 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4, 18-6, 18-8 AWG
Item #: 46111357
Brand: Schneider Electric
Model #: M9U31206
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60H-DC - Supplementary Protection for Direct Current
Amperage
6
Number of Poles
2
Breaking Capacity
20 kA @ 220 VDC; 10 kA @ 440 VDC; 6 kA @ 500 VDC; 5 kA @ 12-500 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
500 VDC
Wire Size (AWG)
18-4; 18-6; 18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
1.4200
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 15 Amp, 600Y/347 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41383829
Brand: Square D
Model #: BGA260151
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
15
Number of Poles
2
Breaking Capacity
65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 100 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 87.4mm Deep x 162.6mm High x 104.7mm Wide
Item #: 56747363
Brand: Square D
Model #: HDP36100
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
100
Number of Poles
3
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 VAC
Maximum Operating Temperature (F)
104
Overall Depth (Decimal Inch)
3.4400
Overall Depth (mm)
87.40
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
For Use With
Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met
CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 400 Amp, 600 V, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings
Item #: 49788094
Brand: Square D
Model #: LHL26400
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
400
Number of Poles
2
Breaking Capacity
25 kA @ 600 VAC; 35 kA @ 480 VAC; 50 kA @ 125 VDC; 50 kA @ 250 VDC; 65 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 V
Standards Met
CCC; CSA; IEC; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 60 Amp, 277 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41398850
Brand: Square D
Model #: BDA140601
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
60
Number of Poles
1
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 70 Amp, 240 VAC, 2 Pole, Bolt On Miniature Circuit Breaker - 8-2 AWG
Item #: 54423660
Brand: Square D
Model #: QOB270VH
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
70
Number of Poles
2
Terminal Connection Type
Box Lugs
Mounting Type
Bolt-on
Voltage
240 VAC
Wire Size (AWG)
8-2
Standards Met
CSA; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Value Collection - Circuit Breakers Circuit Breaker Type: Type III Circuit Breaker Amperage: 100
Item #: 66438821
Brand: Value Collection
Exact Tooling IR#: 04Product Specifications
Circuit Breaker Type
Type III Circuit Breaker
Amperage
100
Tripping Mechanism
Manual
Mounting Type
Flush Mount
Reset Actuator Type
Button
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 2500 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, 119.3mm Deep x 168-1/2mm High x 210mm Wide
Item #: 56761281
Brand: Square D
Model #: RKF36250
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
2500
Number of Poles
3
Tripping Mechanism
Electronic
Terminal Connection Type
Busbar
Mounting Type
Panel Mount
Voltage
600 VAC
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Overall Depth (Decimal Inch)
4.7000
Overall Depth (mm)
119.30
Overall Height (mm)
168-1/2
Overall Height (Decimal Inch)
6.6300
Overall Width (mm)
210
Overall Width (Decimal Inch)
8.2700
Standards Met
60947-6-2; CE; cUIUs Certification; FCC Certification; IEC 60950; RoHS Compliant; UL 508; UL 60950
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 45 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 V, 18 kA at 347 VAC, 35 kA at 277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41394164
Brand: Square D
Model #: BGA160451
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
45
Number of Poles
1
Breaking Capacity
65 kA @ 240 V; 18 kA @ 347 VAC; 35 kA @ 277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
347 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 60 Amp, 480Y/277 V, 3 Pole, Bolt On Molded Case Circuit Breaker - 35 kA Breaking Capacity, 12, 14 AWG, 4.05 Inch Deep x 5.66 Inch High x 2.94 Inch Wide
Item #: 69668663
Brand: Square D
Model #: EGB34060
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
60
Number of Poles
3
Breaking Capacity
35 kA
Terminal Connection Type
Lug
Mounting Type
Bolt-on
Voltage
480Y/277 V
Wire Size (AWG)
12; 14
Overall Depth (Decimal Inch)
4.0500
Overall Height (Decimal Inch)
5.6600
Overall Width (Decimal Inch)
2.9400
For Use With
NF Panelboard
Standards Met
CSA; HACR Rated; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 20 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 65 kA at 480 VAC, 25 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41396953
Brand: Square D
Model #: BJL26020
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
20
Number of Poles
2
Breaking Capacity
100 kA @ 240 VAC; 65 kA @ 480 VAC; 25 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 2 Amp, 480Y/277 Volt, 4 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46118196
Brand: Schneider Electric
Model #: M9F21402
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60SP - Supplementary Protection
Amperage
2
Number of Poles
4
Breaking Capacity
14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
480Y/277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
2.8400
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 15 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide
Item #: 56788292
Brand: Square D
Model #: QOUR1155283
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
15
Number of Poles
1
Breaking Capacity
10 kA @ 120/240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Pressure Plate
Mounting Type
DIN Rail Mounted; Flush Mount; Surface Mount
Voltage
120/240 VAC
Wire Size (AWG)
14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch)
2.9200
Overall Depth (mm)
74
Overall Height (mm)
103
Overall Height (Decimal Inch)
4.0500
Overall Width (mm)
19
Overall Width (Decimal Inch)
3/4
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 150 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG
Item #: 54522321
Brand: Square D
Model #: HGL36150
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
150
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC; 20 kA @ 250 VDC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0
Standards Met
RoHS Compliant
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 200 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 87.4mm Deep x 191mm High x 104.7mm Wide
Item #: 54522206
Brand: Square D
Model #: JDL36200SA
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
200
Number of Poles
3
Breaking Capacity
14 kA @ 600 VAC; 18 kA @ 480 VAC; 25 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 VAC
Maximum Operating Temperature (F)
104
Overall Depth (Decimal Inch)
3.4400
Overall Depth (mm)
87.40
Overall Height (mm)
191
Overall Height (Decimal Inch)
7.5200
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
For Use With
Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met
CSA Certified; IEC 647-2 Icu/Ics; NOM; RoHS Compliant; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 1 Amp, 277 Volt, 1 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46121000
Brand: Schneider Electric
Model #: M9F42101
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60BP - Branch Protection
Amperage
1
Number of Poles
1
Breaking Capacity
3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC; 10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 60 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
4.0600
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
0.7100
For Use With
OEM Panel
Standards Met
UL 489; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 10 Amp, 240 VAC, 2 Pole, Panel Mount Miniature Circuit Breaker - 14-2 AWG
Item #: 56836950
Brand: Square D
Model #: QOU2101201
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
10
Number of Poles
2
Terminal Connection Type
Box Lugs
Mounting Type
Panel Mount
Voltage
240 VAC
Wire Size (AWG)
14-2
For Use With
Auxiliary Switch 1B
Standards Met
CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41393901
Brand: Square D
Model #: BDL26030LU
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
2
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 2 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46120804
Brand: Schneider Electric
Model #: M9F42202
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60BP - Branch Protection
Amperage
2
Number of Poles
2
Breaking Capacity
6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 14 kA @ 240 VAC; 10 kA @ 125 VDC; 10 kA @ 480Y/277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
480Y/277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
4.0600
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
1.4200
For Use With
OEM Panel
Standards Met
UL 489; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 60 Amp, 250 VDC, 480 VAC, 2 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 240 VAC Breaking Capacity, 14-1/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 2-3/4 Inch Wide
Item #: 04882973
Brand: Eaton Cutler-Hammer
Model #: EHD2060L
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
60
Number of Poles
2
Breaking Capacity
18 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Voltage
250 VDC; 480 VAC
Wire Size (AWG)
14-1/0
Overall Depth (Decimal Inch)
3.3800
Overall Depth (Inch)
3-3/8
Overall Height (Decimal Inch)
6
Overall Width (Inch)
2-3/4
Standards Met
CSA Listed; UL Listed 1053; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It